Consultancy Laboratories (OPC) Pvt. Ltd.
Gatih

Mobirise Website Builder

Vision

Gatih’s vision is to become an indispensable Laboratories that brings its efficient ,compact and precision technologies to achieve sustainability in the State ,Society.

MISSION

Contributing towards better Environment by providing state-of-the-art testing & monitoring solution.

    * To follow and suggest industry to implementation of Water (Prevention and Control of Pollution )Act ,1974 Section 17 (2) ,Air(Prevention And Control of Pollution ) Act ,1981, Section -17(2) as per Environment protection Acts/Rules as per CPCB guidelines.

* Our mission to make polluted industry to take prevention and control of water pollution and maintaining or restoring the wholesomeness of water by treating sewage , industrial effluents etc., protecting / conserving natural water to statutory norms and reducing , recycling and safe –disposing solid wastes conforming to statutory norms.

* Our mission to do industrial monitoring stack emission, ambient air quality , monitoring of urban and industrial premises ,as per it’s nature .

* To do noise level monitoring in industry working zone. 

FROM CEO DESK

    Every entrepreneur has a dream to have his/her own organization ; irrespective of domain & vertical it deals in (industrial plants, healthcare, travel & hospitality etc. )well to have one such and run it smoothly on day-to-day basis it requires adhering proper guidelines issued by different government organization.
One such important government organization is CENTRAL POLLUTION CONTROL BOARD (CPCB). While establishing a new firm, Environment clearance is required followed by applying for its ‘Consent to Establish’ and ‘Consent to operate’. One of the important and very common norms is to follow And maintain Water Act, 1974, Section-17(2) defines the function of state board and Air Act, 1981, Section -17(2) defines the function of state board.
We at Gatih Laboratories (OPC) Pvt. Ltd. Help various industries/ Infrastructures to establish this practice by fulfilling all types of pollution norms, Which are mandatory time to time. We provide guidelines, best practices, how to Control Air pollution and utilization of water management .
We are using the latest method of Testing & Using latest Equipments going forward we will be in sink with upcoming technology.
So, Gatih Laboratories (OPC) Pvt. Ltd. Is your one-stop solution for all your environmental clearance needs. TOGETHER WE CAN SERVE OUR PLANET EARTH BETTER. 
Mobirise Website Builder

FROM DIRECTOR DESK 

“You cannot protect the environment unless you empower people, you inform them, and you help them understand that these resources are their own, that they must protect them”
Our Aim is to aware people that how he/she, individually can do small Contribution in making environment clean in addition to check Air and water quality by doing testing at our NABL Lab .
Mobirise Website Builder

Scope at Gatih Consultancy

               We at Gatih Consultancy provide end to end facilities starting from establishment of an Industry, hotel, hospitals, etc. getting NOC for there operations and then meeting up the mandatory clause mentioned in compliances issued by CECB and maintaining them.
Applying and issuing of EC , CTE, CTO.
* Preparation of six month compliance report for EC.
* Monitoring of Air, water , Noise as per CPCB with ISO 17025 standards.
* Installation of ETP/STP.
* NOC and renewal of CTO.
* NOC for with drawing ground water from CGWA.
* Installation of Telemetry Meter and Piezometor
(As suggested by CGWA) 

Audit Reports

As asked by CECB audit reports of all the units should be audited by reputed Institutions like IIT,NIT, etc. within six month of time interval after issuing of there CTO.

          We Gatih Consultancy is associated by Jadavpur University, Kolkata to conduct the audits.


We have together successfully delivered various audit reports for sponge iron Plants. Mainly an industry has to submit following audit reports.
* Environment Audit report.
* Performance test of pollution control equipments.
* Fly Ash report.
* Carbon Sequestration.
* Cost benefit Analysis Standy 

ORGANIZATION STRUCTURE

Mobirise Website Builder

SCOPE OF WORK- BRIEF

Ambient Air Monitoring

Particulate matter (PM 10), Particulate matter (PM2.5), Sulfur Dioxide (as So2)
Oxide of Nitrogen (No2)

Fugitive Emission Monitoring – Suspended Particulate Matter (SPM)
Stack Emission Monitoring

Particulate matter , Oxides of Nitrogen (Nox) Sulphur Dioxide (SO2)
Ambient Noise (Source/DG) Monitoring

Ambient Noise Leq(dB(A))
Water Testing in our Lab   

        Drinking Water, Ground Water, Industrial Water, Surface Water- Swimming Water Construction water, Water from water Purifiers, Waste water (Effluents/Sewage) 
                                                                                                                                                                                  Drinking Water: Calcium (as Ca), Chloride (as C1), Electrical Conductivity,
FLUORIDE, IRON, Magnesium, Nitrate as NO3-, pH at 27oC, POTASSIUM,
SODIUM, Sulphate (as So4) , Total Alkalinity, Total Dissolved Solid (TDS),
Total hardness , total suspended solid (TSS).

      Ground Water : Calcium(as Ca), Chloride (as C1), Electrical Conductivity,
Filterable residue solid(total dissolved solid), FLUORIDE, IRON,
Magnesium, Nitrate as NO3-, pH at 25oC, Sulphate (as SO4-),
Total Alkalinity, Total Hardness, Total Suspended Solid

      Industrial Water : Chloride (as C1), Biochemical oxygen demand ,(BOD) at 27oC calcium (as Ca), Chemical oxygen Demand (COD) , Electrical Conductivity, Magnesium , pH at 25oC, sulphate (as SO4-), Total Alkalinity, Total Dissolve Solids Total Hardness, Total Suspended Solid.

  Surface Water : Biochemical Oxygen Demand –BOD (3 Days at 27oC) Calcium, Chemical Oxygen, Demand (COD), Chloride (as C1), Electrical Conductivity Magnesium, pH at 25oC, sulphate (as SO4-), Total Alkalinity, Total Dissolve Solid Total Hardness, Total Suspended Solid.

       Construction water : Acidity(Neutralize 100 ml sample of water using 0.02 N NaOH) Alkalinity(neutralize 100 ml sample of water using 0.02 N H2SO4),chloride (as C1) Filterable residue (TotalDissolved Solid), pH at 27oC, sulphate ( as SO4), Total Suspended Solid,(TSS).

        Water from water Purifiers : FLUORIDE, IRON, POTASSIUM

       Waste water (Effluents /Sewage) : : Oil and Grease, pH at 27 oC, total suspended, solid(TSS), Biochemical Oxygen Demand(BOD), Chemical Oxygen Demand(COD).

      

EQUIPMENTS LIST

    *WATER EQUIPMENTS: 


Electronic Balance
Ph meter
Conductivity Meter
Cod Digestion Apparatus
Uv-vis. Spectrophotometer
Bod Digestion
Hot Plate
Muffle Furnance
Hot Air Oven
Water Baath
Flame Photo Meter
Flame photometer Compressor
Magnetic stirrer With Hot Plate
Digital Barometer


                      




*AIR EQUIPMENTS :

High Volume Sampler
Stack Sampler Rotameter
Rotameter Gaseous Sampling Attachment
RDS Time Totalizer
Pm-10/2.5 Time Totalizer
Pm-10/2.5 Dry Gas Meter
RDS Orifice Manometer Flow
Stack Thermocouple With Temperature Indicator
S-type Pilot Tube, Sound Level Meter
Stack Sampler Stop Watch
Stack Sampler Pressure Indicator
Stack sampler Vaccume Gauge
Top Loading Calibrator
Pm 10/pm 2.5 sampler Data Logger (flow Rate)
Pm 10/pm 2.5 sampler Data Logger(Time)
Pm 10/pm 2.5 sampler Data Logger(ambient & Filter Tem)
Pm 10/pm 2.5 sampler Barometric Pressure
Flow Celebrator For Dgm & Rotameter (dry Gas Meter)
Flow Celebrator For Dgm & Rotameter (timer)
Stack Sampler Rotameter (Spm)

SCOPE PIPELINE FOR NABL

1.AMBIENTAIR : WORK PLACE, MONOTORING, CARBON MONOXIDE,AMMONIA, OZONE
2.STACK EMISSION : CARBON MONOXIDE
3.WATER : FREE RESIUDUAL CLORINE, TURBIDITY, COLOR, TASTE, ODOUR, FIXED RESIDUAL (INORGANIC 

LIST OF CLIENTS

• Shree Raipur Cement Plant , Baloda Bazar
• Sarda Energy and Minerals Ltd,Raipur
• Nutan Ispat & Power Pvt Ltd,Raipur
• Ghankun Ispat Pvt Ltd, Raipur
• Hanuman Ispat Pvt Ltd,Raipur
• Maruti Ferrous Pvt Ltd,Raipur
• Vraj Iron and Steel Ltd, Raipur
• MMI Narayana Hospital, Raipur
• Balco Medical Center Nava Raipur
• Shree Narayana Hospital , Raipur
• Marriott Courtyard Hotel , Raipur
• Hyatt Hotel, Raipur
• Sayaji Hotels Ltd.,Raipur
• Kalpataru Projects International Limited,Abhanpur
• Reliance Industries Ltd.,Abhanpur
• Vossloh Beekay Casting Limited ,Bhilai
• JSW Steel Limited, Raigarh
• Ind Synergy Ltd., Raigarh
• Sunil Ispat and Power Pvt Ltd, Raigarh
• Sunil Sponge Pvt Ltd, Raigarh
• Salasar Steel & Power Ltd.,Raigarh
• Shri Shyam Ispat (india) Pvt Ltd., Raigarh
• Singhal Energy Pvt Ltd., Raigarh
• Maa Mangla Ispat Pvt Ltd., Raigarh
• Maa Shakambari Stell Ltd., Raigarh
• Satya Power & Ispat Ltd., Bilaspur
• Marriott Courtyard Hotel, Bilaspur
• Karnikripa Power Pvt. Ltd., Mahasamund
• APL Apollo Building Products Pvt Ltd. Balodabazar 

Mobirise Website Builder
Mobirise
Mobirise
Mobirise
Mobirise

NABL CERTIFICATE

Mobirise Website Builder

NABL CERTIFICATE

Mobirise Website Builder
Mobirise

Contacts

Phone

9818549935,9818446188

Email

amit.chandravanshi@gatihconsultancy.com
shubham.sharma@gatihconsultancy.com

Address

GATIH LABORATORIES (OPC) PVT.LTD. 
Bungalow No.1 , Balaji Greens City,
Sondongri,Near Heerapur,Raipur (C.G.) 492099

Consultancy Laboratories (OPC) Pvt. Ltd.
Gatih

Thanks

Free AI Website Creator